Heat Pump for Water Heating

Heat Pump for Water Heating

A Termojet water heating heat pump takes heat from the air and uses about 3.8 times less electricity than a conventional boiler with an electric heating element. For the home — the Hot Spot heat pump water heater of 200, 250 and 300 l: the tank and the heat pump share one body and are installed in place of the old boiler. For hotels, restaurants and production facilities — commercial Ecostar EVI and Greenstar units of 10.5–188 kW.

Boiler volume selection
Found: 14
Series:

Hot Spot heat pump water heaters

200–300 l · 1.8–2.4 kW · 230 V · 2 kW backup electric heating element · WiFi

Heat pump water heater 200 L Hot Spot
Hot Spot

Heat pump water heater 200 L Hot Spot

NE-F20HWR2-200E-UPC

All-in-one domestic hot water heat pump with integrated 200L cylinder. R134a refrigerant, COP up to 4.0.

  • 200 л
  • 1,8 кВт
  • ТЕН 2 кВт
131 405 ₴
incl. VAT
Heat pump water heater 250 L Hot Spot
Hot Spot

Heat pump water heater 250 L Hot Spot

NE-F25HWR2-250E-UPC

All-in-one domestic hot water heat pump with integrated 200L cylinder. R134a refrigerant, COP up to 4.0.

  • 250 л
  • 2,4 кВт
  • ТЕН 2 кВт
Price on request
Heat pump water heater 300 L Hot Spot
Hot Spot

Heat pump water heater 300 L Hot Spot

NE-F20HWR2-300E-UPC

All-in-one domestic hot water heat pump with integrated 200L cylinder. R134a refrigerant, COP up to 4.0.

  • 300 л
  • 2,4 кВт
  • ТЕН 2 кВт
152 963 ₴
incl. VAT

Commercial hot water heat pumps

Ecostar EVI 10.5–188 kW · Greenstar 52–182 kW · 380 V

Greenstar

R410a · 52–182 kW · 380 V · 5 products

Commercial DHW heat pump on R410a. High-capacity heating for hotels, gyms and residential complexes.

Water heating heat pump 52 kW Greenstar
Greenstar

Water heating heat pump 52 kW Greenstar

NE-F520HWR3T-U

Commercial DHW heat pump on R410a. High-capacity heating for hotels, gyms and residential complexes.

  • 52 кВт
  • 380 В
  • R410a
500 519 ₴
incl. VAT
Water heating heat pump 74 kW Greenstar
Greenstar

Water heating heat pump 74 kW Greenstar

NE-F740HWR3T-U

Commercial DHW heat pump on R410a. High-capacity heating for hotels, gyms and residential complexes.

  • 74 кВт
  • 380 В
  • R410a
667 239 ₴
incl. VAT
Water heating heat pump 78 kW Greenstar
Greenstar

Water heating heat pump 78 kW Greenstar

NE-F780HWR3T-U

Commercial DHW heat pump on R410a. High-capacity heating for hotels, gyms and residential complexes.

  • 78 кВт
  • 380 В
  • R410a
718 620 ₴
incl. VAT
Water heating heat pump 90 kW Greenstar
Greenstar

Water heating heat pump 90 kW Greenstar

NE-F905HWR3T-U

Commercial DHW heat pump on R410a. High-capacity heating for hotels, gyms and residential complexes.

  • 90 кВт
  • 380 В
  • R410a
872 559 ₴
incl. VAT
Water heating heat pump 182 kW Greenstar
Greenstar

Water heating heat pump 182 kW Greenstar

NE-F1850HWR3T-U

Commercial DHW heat pump on R410a. High-capacity heating for hotels, gyms and residential complexes.

  • 182 кВт
  • 380 В
  • R410a
1 616 895 ₴
incl. VAT

Ecostar EVI

R410a · 10,5–188 kW · 380 V · 6 products

Commercial DHW heat pump with EVI technology on R410a. Stable operation at ambient temperatures down to −15°C.

Water heating heat pump 10.5 kW Ecostar EVI
Ecostar EVI

Water heating heat pump 10.5 kW Ecostar EVI

NE-F105HWR3TEVI-U

Commercial DHW heat pump with EVI technology on R410a. Stable operation at ambient temperatures down to −15°C.

  • 10,5 кВт
  • 380 В
  • R410a
Price on request
Water heating heat pump 18.5 kW Ecostar EVI
Ecostar EVI

Water heating heat pump 18.5 kW Ecostar EVI

NE-F185HWR3TEVI-U

Commercial DHW heat pump with EVI technology on R410a. Stable operation at ambient temperatures down to −15°C.

  • 18,5 кВт
  • 380 В
  • R410a
Price on request
Water heating heat pump 37 kW Ecostar EVI
Ecostar EVI

Water heating heat pump 37 kW Ecostar EVI

NE-F370HWR3TEVI-U

Commercial DHW heat pump with EVI technology on R410a. Stable operation at ambient temperatures down to −15°C.

  • 37 кВт
  • 380 В
  • R410a
Price on request
Water heating heat pump 52 kW Ecostar EVI
Ecostar EVI

Water heating heat pump 52 kW Ecostar EVI

NE-F520HWR3TEVI-U

Commercial DHW heat pump with EVI technology on R410a. Stable operation at ambient temperatures down to −15°C.

  • 52 кВт
  • 380 В
  • R410a
Price on request
Water heating heat pump 95 kW Ecostar EVI
Ecostar EVI

Water heating heat pump 95 kW Ecostar EVI

NE-F950HWR3TEVI-U

Commercial DHW heat pump with EVI technology on R410a. Stable operation at ambient temperatures down to −15°C.

  • 95 кВт
  • 380 В
  • R410a
Price on request
Water heating heat pump 188 kW Ecostar EVI
Ecostar EVI

Water heating heat pump 188 kW Ecostar EVI

NE-F1880HWR3TEVI-U

Commercial DHW heat pump with EVI technology on R410a. Stable operation at ambient temperatures down to −15°C.

  • 188 кВт
  • 380 В
  • R410a
Price on request

Hot Spot instead of an electric boiler: how much electricity it saves

The Hot Spot 200 l delivers 1.8 kW of heat while consuming 0.47 kW: the COP is 3.82. A boiler with an electric heating element has a COP of 1 — all the electricity consumed turns into heat one to one. So for the same volume of hot water, Hot Spot uses about 3.8 times less electricity. The price of Hot Spot is higher; the difference pays back through electricity bills.

ModelHeat pumpElectric heating elementCOPHot waterConsumption
Hot Spot 200 l1.8 kW2 kW3.8239 l/h0.47 kW
Hot Spot 250 l2.4 kW2 kW3.8852 l/h0.62 kW
Hot Spot 300 l2.4 kW2 kW3.8852 l/h0.62 kW

How to choose the boiler volume

Number of peopleVolumeModel
1–2200 lHot Spot 1.8 kW, 200 l
3–4250 lHot Spot 2.4 kW, 250 l
4–6300 lHot Spot 2.4 kW, 300 l

This is a guideline for ordinary consumption. If the house has two bathrooms or many people need water at the same time, choose a larger volume.

2-in-1 boiler or heat pump + indirect-heating boiler

Hot Spot is enough when only hot water is needed and the house is heated by gas, a boiler or electricity: the tank and heat pump in one body are installed in place of the old boiler.

If the house already has a heat pump for heating, it is cheaper to heat the hot water through an indirect-heating boiler: the same air-to-water heat pump then heats both the house and the water.

Commercial models: Ecostar EVI and Greenstar

Ecostar EVIGreenstar
Capacity10.5–188 kW52–182 kW
Power supply380 V380 V
RefrigerantR410aR410a
Water temperatureup to 60 °Cup to 60 °C
Winter operationdown to −25 °C (EVI)down to −15 °C
Suitable sitesrestaurants, small hotels, hospitalslarge hotels, hospitals, production facilities

Installation requirements

Hot Spot is installed in a room with an air temperature from −7 to +43 °C and a volume of more than 15 m³: boiler rooms, garages, basements or utility rooms. Water, a 230 V socket and a condensate drain are connected to the tank.

ModelDimensionsWeight without waterWater connection
Hot Spot 200 lØ570 × 1803 mm96 kgG1/2″
Hot Spot 250 lØ640 × 1802 mm123 kgG3/4″
Hot Spot 300 lØ640 × 2020 mm141 kgG3/4″

FAQ

What boiler volume is needed for a family of 3–4 people?

250 l — Hot Spot 2.4 kW, 250 l. If the house has two bathrooms, choose 300 l.

Where can a heat pump water heater be installed?

In a boiler room, garage, basement or utility room with an air temperature from −7 to +43 °C and a room volume of more than 15 m³. Water connections, a 230 V socket and a condensate drain are required.

How much does a 200 l heat pump water heater cost?

The price of the 200 l Hot Spot is on the product card above, including VAT, installation not included.

Other categories